For routine condition maintenance and life assessment of capacitors, a tester that only shows a single final capacitance reading in microfarads (μF) often fails to deliver sufficient information for seasoned high-voltage test specialists. Questions remain: “The measured capacitance is within limits, but has the dielectric loss angle inside the capacitor deteriorated?” “Is there faint arc impedance at the contact surface of the internal fuse?” “Is the phase angle of the energized circuit normal, or are there reversed homonymous terminals or minor inductive crosstalk?”
Without synchronous display of multi-dimensional electrical parameters, subtle incipient faults may easily escape the inspector’s attention.
The HZRG‑III Capacitance and Inductance Tester developed by Baoding Huazheng Electric Manufacturing Co., Ltd. integrates the concept of a vector analyzer into a portable field instrument, enabling direct and synchronous reading of all parameters on one screen.
7.0-inch 1024×600 High-Definition Touchscreen, Clear View Day and Night The HZRG‑III is fitted with a premium 7.0-inch industrial color touch LCD on the front panel: Fine 1024×600 resolution: The interface is neatly laid out with large fonts for core parameters; it avoids glare and whitening under strong daylight and delivers soft, clear visuals for night patrols. Full touch operation with one-click Chinese/English switching: Users can toggle between full Chinese and full English interfaces. The menu structure is streamlined, and mode settings and parameter adjustments are completed by tapping on-screen icons.
Six Core Parameters Displayed in Real Time on the Same Screen for Comprehensive Fault Diagnosis On the result page after measurement, the HZRG‑III not only calculates the capacitance or inductance of the DUT, but also presents a full set of underlying electrical vector parameters that indicate equipment health: Test Voltage (U): Accurate RMS value of the applied excitation voltage; Test Current (I): True response current in microampere or milliampere scale through the measured branch; Test Frequency (f): Clear indication of the excitation frequency (55 Hz); Measured Impedance (Z): Direct reading of the total complex impedance of the circuit; Phase Angle (φ): Precise measurement of the angle between voltage and current, for quick identification of purely capacitive (near 90°) or purely inductive response, and instant detection of reversed cable wiring or phase sequence errors; Converted Reactive Power per Phase (Q): After entering the rated system voltage, the instrument automatically calculates the rated reactive power output (kvar) of the phase using measured capacitance formulas for direct comparison with the nameplate and factory technical specification.
Multi-parameter simultaneous display and transparent vector analysis. More than a simple capacitance meter, the HZRG‑III serves as a portable integrated diagnostic tool for reactive power compensation equipment.