For the ampere-second characteristics of DC circuit breakers, the time range spans extremely wide: from long-time delay tripping of thousands of seconds under minor overload to instantaneous operation within tens or even several milliseconds under short-circuit heavy current. Especially when verifying the instantaneous magnetic trip characteristics of circuit breakers, the capability to accurately capture the millisecond-level time point at which contacts separate, the arc extinguishes and the current is cut off directly tests the sampling chip and logic judgment capability of the test instrument.
If the timing system of the test instrument relies on feedback from ordinary mechanical relay contacts, or uses a low-bit sampling chip with slow conversion rate, arc jitter generated upon contact separation is prone to misjudgment. This introduces a systematic error of tens of milliseconds in the measured operating time of the circuit breaker, which further leads to incorrect evaluation of the selectivity coordination gradient.
To tackle this timing challenge at microsecond and millisecond levels, the HZDK-1000 DC Switch Ampere-Second Characteristic Tester developed by Baoding Huazheng Electric Manufacturing Co., Ltd. adopts high-performance design for its data acquisition front end and clock counting unit.
Multiple High-Precision Sensors with Auto-Ranging, 14-bit High-Speed AD Acquisition The HZDK-1000 is equipped with a multi-channel precision signal conversion and sampling system:
Auto-ranging via multiple sensors: The unit is fitted with several high-precision wide-band sensors for low and high currents. When testing low-current circuit breakers (1A~50A) or high-current circuit breakers (200A~1000A), the system automatically switches to the optimal current gain range according to the set target current, ensuring high signal-to-noise ratio across the full measurement range.
High-performance 14-bit high-speed AD chip: A high-resolution 14-bit analog-to-digital converter continuously tracks the current waveform of the output circuit at millisecond intervals, sensitively identifying subtle sudden current drops.
Fully Automatic Start-Stop Logic: Timing Starts Upon Current Output, Trip Time Latches Upon Interruption The intelligent fully automatic test process greatly simplifies on-site operation for technicians:
Clear trigger start point: After the operator clicks “Start” on the interface, the high-precision internal hardware timer synchronously triggers at the microsecond instant when current output and voltage establishment begin.
Automatic trip state capture: During heavy current impact, the system monitors the conduction status of the main circuit in real time via high-frequency sampling. Once the internal contacts of the DC circuit breaker open and the circuit current drops to zero, the system instantly captures the trip event, stops the timer immediately, and automatically latches the final millisecond-level operating time on the result display.
Ultra-wide timing range: The onboard time recording range covers 0~999999 seconds. It can continuously and accurately record light-load inverse-time overload endurance lasting up to hundreds of hours, as well as millisecond-level electromagnetic instantaneous tripping.
High-sensitivity capture, clear millisecond resolution. The HZDK-1000 converts the complex dynamic breaking process of DC circuit breakers into reliable, definite time readings on the display.